    CRITICOOL/ CRITICOOL-FC Air Cooled Chiller(with free cooling)

    Brief IntroductionThe CRITICOOL series air-cooled water chilling units with the wide cooling capacity range and high reliability are applicable to the large-scale data center and various industrial pr

    Top

    information

    Brief Introduction
    The CRITICOOL series air-cooled water chilling units with the wide cooling capacity range and high reliability are applicable to the large-scale data center and various industrial process application sites. The CRITICOOL-FC units are equipped with the additional free cooling coils, which may provide free cooling when the outdoor temperature is relatively low so as to greatly reduce the cooling energy consumption of air conditioners for data center. Moreover, the series units adopt the efficient and reliable screw compressor and may be optionally equipped with unit built-in pump unit boxes. Once the water pipe and power supply cable are connected on the site, then the unit can be ready-to-use. And such unit may be installed outside the room without occupying space of computer room.
    Capacity
    105~1493kW  
    Applications
    Commercial PlacesIndustial Places
    Features
    Free cooling
    Patented three-way adjustment technology; the free cooling coils are made of special copper tube aluminum-made fins and steel plating base of anodized aluminum alloys or sprayed with epoxy resin; Thus, the operation cost will be greatly reduced and the service life of such unit will be extended considerably as well.

    Low-temperature starting and operation
    With the advanced systematic design, special liquid impact prevention compressor and continuous & stepless regulating condensing airflow, it will ensure that the system will be stable under high-pressure operation.

    High reliability
    All components have been detected strictly. And each unit may be standby for each other so as to ensure the requirement of high reliability of data center.
    Reasonable design and easy maintenance
    The unit is of reasonable design and compact structure and is easy for maintenance;

     

    Noise control
    The low-noise unit compressor is installed within the independent and closed space of the unit so that the influence of the noise will be reduced to the lowest.


    Quality management system(ISO9001)
     

    Factory tests 

    Options
    Control of water pump
    The operation of water pump will be completely controlled by a computer. And the user has no need to  equip a pump room additionally.
    Ice storage function