The outdoor air-cooled condensers include three series: CMD, CME and AMAE.


CMD air-cooled condenser is used for small precision temperature control unit or base station temperature control unit. The covers of CMD condenser are produced by coating sheet metal, which has characteristics of anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Only vertical installation of the condenser is available.
 

The covers of CME air-cooled condenser are produced by aluminum sheet, which has characteristics of light weight, anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Vertical or horizontal installation of the condenser is available.

The covers of AMAE air-cooled condenser are produced by aluminum sheet, which has characteristics of light weight, anti-corrosion, anti-rust, etc. The condenser is equipped with EC axial fan which has characteristics of big air volume, lower power consumption and adjustable fan speed and high efficiency heater exchanger. The condenser is suitable for high temperature working conditions. Vertical or horizontal installation of the condenser is available.


The covers of CMEH dry cooler are produced by aluminum sheet, which has characteristics of light weight, anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Vertical or horizontal installation of the condenser is available,free cooling type unit can choose PUG pump group box.

CMD/CME

Model

 

CMD3

CMD4

CMD5

CMD6

CME4

CME5

CME8

CME10

CME15

CME20

CME25

Power source

 

 

220V-1Ph-50Hz

Capacity (1)

kW

9.3

13.7

20.4

23.6

15.6

20.5

29.6

35.4

47.6

67.4

73.1

Fan

 

 

 

 

 

 

 

 

 

 

 

 

Qty. of fan

n.

1

1

1

1

1

1

1

1

2

2

2

Air volume

m3/h

4400

4100

5600

5800

4400

5600

10100

9700

11600

20100

19100

Input power

kW

0.28

0.28

0.37

0.37

0.28

0.37

0.63

0.63

0.74

1.26

1.26

Input current

A

1.3

1.3

1.7

1.7

1.3

1.7

3

3

3.4

6

6

Gas pipe

ODF

5/8"

5/8"

5/8"

5/8"

16

19

22

22

22

28

35

Liquid pipe

ODF

1/2"

1/2"

1/2"

1/2"

12

12

16

16

19

19

22

Width*Depth*Height

mm

808*509*789

1004*509*930

1250*509*930

840*475*770

1140*475*770

1340*620*1070

1540*620*1070

2400*630*1135

Weight

Kg

29

35

43

92

37

47

95

110

130

155

185

(1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃.

 

AMAE

Model

 

AMAE5

AMAE6

AMAE8

AMAE10

AMAE12

AMAE15

AMAE18

AMAE20

Power source

 

220V/1Ph/50Hz

Capacity (1)

kW

24.2

29.7

36.2

41.3

50.7

57.2

62.4

74.3

Fan

 

 

 

 

 

 

 

 

 

Qty. of fan

n.

1

1

1

1

2

2

2

2

Air volume

m3/h

12500

11600

11800

11500

23500

22000

23400

22600

Input power

kW

0.63

0.63

0.63

0.63

1.26

1.26

1.26

1.26

Input current

A

2.8

2.8

2.8

2.8

5.6

5.6

5.6

5.6

Gas pipe

ODF

19

19

19

22

22

22

22

28

Liquid pipe

ODF

16

16

16

16

16

16

19

19

Width*Depth*Height

mm

1365*620*1080

1665*620*1080

1985*620*1080

2790*620*1080

Weight

Kg

103

116

135

152

173

182

206

220

(1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃.

 

CMEH

Model

 

CMEH20

CMEH30

CMEH40

CMEH50

CMEH60

CMEH70

CMEH80

Power source

 

220V/1Ph/50Hz

 

Capacity

kW

23.2

31.2

45.3

56.7

61.5

75.2

83.1

Heat exchange coil

 

 

 

 

 

 

 

 

Water flow

m3/h

3.5

5.2

6.2

9.3

10.2

10.6

11.8

Pressure drop

kPa

71.1

68.2

58.7

57.6

69.1

72.3

78.5

Fan

 

 

 

 

 

 

 

 

Qty. of fan

n.

1

1

2

2

2

3

3

Air volume

m3/h

12100

11200

22800

23200

21800

33600

32400

Nominal mechanical power

kW

0.75

0.75

1.5

1.5

1.5

2.3

2.3

Max electric absorption

A

3.3

3.3

6.6

6.6

6.6

10.1

10.1

Width*Depth*Height

mm

1350*620*1070

1980*620*1120

2700*620*1120

3580*620*1120

Weight

Kg

95

115

145

175

195

235

255

(1) Heat dissipating capacity @ inlet air temperature 35℃, inlet water temperature 45℃.

 

PUG

Unit model

 

PUG5

PUG10

PUG15

PUG20

PUG25

Water flow

m3/h

23.2

31.2

45.3

56.7

61.5

Pump head

m

26

27

28

26

26

Pump qty. (1)

n.

1

1

2

2

2

Input power

kW

0.75

0.75

1.5

1.5

1.5

Input current

A

3.3

3.3

6.6

6.6

6.6

Connection tube size

 

 

 

 

 

 

Water inletΦ

in

1-1/2″

1-1/2″

2″

2″

2″

Water outletΦ

in

1-1/2″

1-1/2″

2″

2″

2″

Physical data and weight

 

 

 

 

 

 

Length

mm

1390

1390

1390

1390

1390

Width

mm

750

750

750

750

750

Height

mm

1050

1050

1050

1050

1050

Weight

kg

115

120

150

163

180

(1)Each unit is equipped with two pumps, use one and the other one stand by. Above parameters is rated at signal pump works.